GTACSR & GZTACSR Conductor

Minimum Order Quantity: 2KM;
Payment Type: T/T, L/C, MoneyGram, Credit Card, Western Union, Cash;
Shipping: Shipping fee and delivery date to be negotiated. Chat with supplier now for more details;
Secure Payments: Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols;
Delivery Terms: FOB, CFR, EXW, FAS, DDP;
Payment Currency: USD, EUR, CAD, AUD, GBP, CNY

Share:

Product Description

Thermal Resistant Aluminum Conductors Steel Reinforced with GAP (GzTASCR)

Gap-type ZT-aluminum conductor steel reinforced (GZTACSR) uses heat-resistant aluminum over a steel core.

GTACSR & GZTACSR Conductor Application

High Temperature Thermal Resistant Alloy Conductor : Aluminum-Zirconium wires (Type-AT1 or AT3), concentrically stranded over a steel core having a small gap between the Steel core & thermal-resistant aluminum alloy layer. These combination offers best Mechanical as well as Electrical Characteristics. Extra High Strength Galvanized Steel (EST); or aluminum-claded Extra High Strength Steel (AW). Additional corrosion protection is achieved as High Temperature Grease is applied in Between GAP of Conductor.

GZTACSR Conductor Construction

Aluminium-Zirconium wires (Type-AT3 or AT-1), concentrically stranded over a steel core maintaing gap between the Steel core and first Aluminium Layer.

Values based on following Specifications:

• Thermal-resistant aluminium alloy wires (Type-AT3 or AT1) for overhead line conductor as per IEC 62004

• Concentric lay stranded overhead electrical conductors IEC 61089, IEC 62420

• Zinc-coated steel wires for stranded conductors IEC 888, ASTM B957 & more

• Zinc–5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire EN 50540, ASTM B802, ASTM B803 or ASTM B958.

• Aluminium Clad Steel Wires, IEC 61232, ASTM B415, EN 50540 & More

GZTACSR Conductor Features

• These can operate upto 210°C with specified strength loss,

• Can carry 100~150% more current as that of ACSR of the same size.

• For uprating lines, no modifications or reinforcement is required to the existing towers

• Limiting the sag increase with the increase of the temperature by the thermal expansion coefficient above knee-point related to the steel core

GZTACSR Conductor Specifications
GTACSR & GZTACSR
Conductor Size Stranding Cross-Sectional Area Diameter of Complete Conductor Weight Rated Strength DCResistance @20°C Current Capacity
No. of Wires Wire diameter TAL Steel Total TAL Steel Total with Grease Extra High Strength Ultra High Strength
TAL Steel TAL Steel @ 85°C @ 150°C @ 210°C
(mm²) (No.) (No.) (mm) (mm) (mm²) (mm²) (mm²) (mm) (Kg/Km) (Kg/Km) (Kg/Km) (KN) (KN) (Ω/Km) (Ampere) (Ampere) (Ampere)
175 8/12 7 3.35 (TW) 2.10 176.20 24.25 200.45 17.50 486.98 189.44 691.42 66.14 66.87 0.1668 409 698 859
190 12/16 7 2.92 (TW) 2.30 187.30 29.08 216.38 18.20 517.66 227.24 761.90 74.44 75.46 0.1569 425 728 896
195 20/12 7 2.40(R)  2.88(TW) 2.20 168.80 26.61 195.41 18.06 466.53 207.91 690.44 69.51 70.31 0.1741 403 689 849
218 18/12 7 2.78(R)   2.94(TW) 2.25 190.50 27.83 218.33 19.10 526.51 217.47 759.98 74.47 75.31 0.1542 433 744 917
240 8/12 7 4.02 (TW) 2.40 253.40 31.67 285.07 20.60 700.35 247.43 964.78 88.34 89.45 0.1159 507 877 1083
248 12/8 7 3.71(TW) 2.40 216.12 31.67 247.79 19.40 597.32 247.43 862.75 83.00 84.11 0.1360 463 796 981
287 18/12 7 3.15(R)   3.43(TW) 2.55 251.00 35.75 286.75 21.77 693.72 279.33 993.04 94.85 96.10 0.1171 510 886 1096
287 20/12 7 2.90(R)  3.55(TW) 2.55 251.00 35.75 286.75 21.77 693.72 279.33 993.04 95.33 96.58 0.1171 510 886 1096
310 16/12 7 3.90(R)  3.69(TW) 2.80 319.40 43.10 362.50 24.40 882.76 336.78 1241.54 116.10 117.60 0.0920 589 1033 1281
400 18/12 7 3.90(R)  4.45(TW) 2.80 401.40 43.10 444.50 26.90 1109.40 336.78 1468.18 129.16 130.67 0.0732 673 1190 1480
410 14/12 7 4.90(R)  3.99(TW) 3.00 414.00 49.48 463.48 27.60 1144.22 386.61 1554.83 138.95 140.68 0.0710 687 1218 1515
439 15/12 7 4.50(R)   4.04(TW) 2.90 392.50 46.24 438.74 26.84 1084.80 361.27 1469.07 132.44 134.06 0.0749 665 1176 1462
462 14/12 7 4.90(R)  3.99(TW) 2.95 414.30 47.84 462.14 27.60 1145.05 373.83 1542.88 136.47 138.14 0.0709 687 1219 1516
540 24/14/10 7 3.55(R)  3.98(TW) 3.10 536.20 52.83 589.03 31.30 1483.12 412.81 1920.93 164.15 166.00 0.0548 799 1436 1793
620 16/12/12 7 4.80(TW) 4.75(TW) 3.47(TW) 3.20 615.70 56.30 672.00 31.50 1703.01 439.88 2168.89 177.96 179.93 0.0478 856 1539 1922
GTACSR/AW & GZTACSR/AW 
Conductor Size Cross-Sectional Area Stranding Diameter of Complete Conductor Weight Rated Strength DC Resistance @20°C Current Capacity
STAL Steel Total No. of STAL Wires No. of STAL Layers No. of Steel Wires Dia. of Steel Wires STAL Steel Total High Strength Extra High Strength
@ 85°C @ 150°C @ 210°C
(mm²) (mm²) (mm²) (mm²) (No.) (No.) (No.) (mm) (mm) (Kg/Km) (Kg/Km) (Kg/Km) (KN) (KN) (Ω/Km) (Ampere) (Ampere) (Ampere)
175 8/12 7 3.35 (TW) 2.10 176.20 24.25 200.45 17.50 486.98 160.46 647.44 57.65 62.26 0.1593 418 714 879
190 12/16 7 2.92 (TW) 2.30 187.30 29.08 216.38 18.20 517.66 192.48 710.14 65.28 69.93 0.1490 436 747 919
195 20/12 7 2.40(R)  2.88(TW) 2.20 168.80 26.61 195.41 18.06 466.53 176.11 642.64 60.20 65.25 0.1652 414 708 871
218 18/12 7 2.78(R)   2.94(TW) 2.25 190.50 27.83 218.33 19.10 526.51 184.21 710.72 64.73 70.02 0.1470 444 762 940
240 8/12 7 4.02 (TW) 2.40 253.40 31.67 285.07 20.60 700.35 209.59 909.94 78.36 83.43 0.1112 518 895 1105
248 12/8 7 3.71(TW) 2.40 216.12 31.67 247.79 19.40 597.32 209.59 806.91 73.03 78.09 0.1295 474 816 1006
287 18/12 7 3.15(R)   3.43(TW) 2.55 251.00 35.75 286.75 21.77 693.72 236.60 930.32 83.59 89.31 0.1117 523 908 1122
287 20/12 7 2.90(R)  3.55(TW) 2.55 251.00 35.75 286.75 21.77 693.72 26.60 720.32 84.07 89.79 0.1117 523 908 1122
310 16/12 7 3.90(R)  3.69(TW) 2.80 319.40 43.10 362.50 24.40 882.76 285.27 1168.03 102.52 109.41 0.0880 602 1056 1310
400 18/12 7 3.90(R)  4.45(TW) 2.80 401.40 43.10 444.50 26.90 1109.40 285.27 1394.67 115.59 122.48 0.0706 685 1212 1507
410 14/12 7 4.90(R)  3.99(TW) 3.00 414.00 49.48 463.48 27.60 1144.22 327.48 1471.70 123.36 131.28 0.0682 700 1242 1545
439 15/12 7 4.50(R)   4.04(TW) 2.90 392.50 46.24 438.74 26.84 1084.80 306.00 1390.80 117.87 125.27 0.0720 678 1200 1491
462 14/12 7 4.90(R)  3.99(TW) 2.95 414.30 47.84 462.14 27.60 1145.05 316.65 1461.70 121.40 129.05 0.0682 700 1242 1545
540 24/14/10 7 3.55(R)  3.98(TW) 3.10 536.20 52.83 589.03 31.30 1483.12 349.67 1832.79 149.36 156.23 0.0536 808 1452 1812
620 16/12/12 7 4.80(TW) 4.75(TW) 3.47(TW) 3.20 615.70 56.30 672.00 31.50 1703.01 372.60 2075.61 162.19 169.51 0.0467 865 1556 1944

 

Case Video

Certificate Display

Factory Tour

Why choose us?

Professional

50+ years of experience Trusted manufacturing expertise since 1969

Professional

50+ years of experience Trusted manufacturing expertise since 1969
Read More

Fast Delivery

Fast global delivery Efficient manufacturing and worldwide shipping

Fast Delivery

Fast global delivery Efficient manufacturing and worldwide shipping
Read More

standards

International standards IEC, ASTM, BS, CSA and other global standards

standards

International standards IEC, ASTM, BS, CSA and other global standards
Read More

High Quality

Strict quality control Comprehensive testing throughout productio

High Quality

Strict quality control Comprehensive testing throughout productio
Read More

FAQs

Who are we?

A Cable Manufacturer Built for Project Supply
Part of Henan Qingzhou Group — specialised in the research, production, sale and service of electrical wire & cable, with two production parks totalling 380,000 m² at the foot of Longevity Mount, Gongyi City, Henan Province, China.

With the professional Qingzhou team we manufacture not only to Chinese standards but strictly to foreign national and international standards including Europe, U.S., Australia and IEC — and we supply one-stop solution service for your power project.

The company manufactures a wide range of electrical cables and conductors, including AAC, AAAC, ACSR bare conductors, low voltage ABC cables, medium voltage power cables, ADSS fiber optic cables, OPGW cables and cable accessories.

Qingzhou cable company has passed ISO9001 quality management system, ISO14001 environmental management system, ISO45001\German TUV certification\CE certification, the company is a finalist for the state power grid and a national”High-tech Enterprise.

Accepted Delivery Terms: FOB,CFR,EXW,FAS,DDP; Accepted Payment Currency:USD,EUR,CAD,AUD,GBP,CNY; Accepted Payment Type: T/T,L/C,MoneyGram,Credit Card,Western Union,Cash; Language Spoken:English,Chinese,Japanese,German,Russian

Yes, we have production line for packing box and cartons. we can make it according to your special requirement. If you are interested in our goods , please kindly send an inquiry to us !

Contact us to get your quote!

Related Products

Contact Us Right Now

Fill out the form to download the brochure