MEDIUM VOLTAGE XLPE POWER CABLES
8.7/15 (17.5) kV
12/20 (24) kV
18/30 (36) kV
8.7/15 (17.5) kV
YHAKXS, A2XSY, NA2XSY - ALUMINIUM CONDUCTOR
YHKXS, 2XSY, N2XSY - COPPER CONDUCTOR
XUHAKXS, A2XS(F)2Y, NA2XS(F)2Y - ALUMINIUM CONDUCTOR
XUHKXS, 2XS(F)2Y, N2XS(F)2Y - COPPER CONDUCTOR
XRUHAKXS, A2XS(FL)2Y, NA2XS(FL)2Y - ALUMINIUM CONDUCTOR
XRUHKXS, 2XS(FL)2Y, N2XS(FL)2Y - COPPER CONDUCTOR
12/20 (24) kV
YHAKXS, A2XSY, NA2XSY - ALUMINIUM CONDUCTOR
YHKXS, 2XSY, N2XSY - COPPER CONDUCTOR
XUHAKXS, A2XS(F)2Y, NA2XS(F)2Y - ALUMINIUM CONDUCTOR
XUHKXS, 2XS(F)2Y, N2XS(F)2Y - COPPER CONDUCTOR
XRUHAKXS, A2XS(FL)2Y, NA2XS(FL)2Y - ALUMINIUM CONDUCTOR
XRUHKXS, 2XS(FL)2Y, N2XS(FL)2Y - COPPER CONDUCTOR
18/30 (36) kV
YHAKXS, A2XSY, NA2XSY - ALUMINIUM CONDUCTOR
YHKXS, 2XSY, N2XSY - COPPER CONDUCTOR
XUHAKXS, A2XS(F)2Y, NA2XS(F)2Y - ALUMINIUM CONDUCTOR
XUHKXS, 2XS(F)2Y, N2XS(F)2Y - COPPER CONDUCTOR
XRUHAKXS, A2XS(FL)2Y, NA2XS(FL)2Y - ALUMINIUM CONDUCTOR
XRUHKXS, 2XS(FL)2Y, N2XS(FL)2Y - COPPER CONDUCTOR
ALUMINIUM CONDUCTOR - Round, stranded and compacted conductor - Class 2 YAHKXS acc . to ZN-TF-501:2002
A2XSY acc . to IEC 60502-2:2005 and BS 6622:2007
NA2XSY acc . to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter |
Insulation |
Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying |
||
Thickness |
Diameter over insulation |
Cross sectional area |
Diameter over metallic screen |
||||||
mm2 |
mm |
mm2 |
mm |
mm |
kg/km |
kN |
m |
||
1x50RMC |
8.25 +0.10 |
4.5 |
18.5 |
16 |
22.4 |
27.1 |
780 |
1.5 |
0.41 |
1x70RMC |
9.5 +0.20 |
4.5 |
19.7 |
25 |
23.6 |
28.4 |
950 |
2.1 |
0.43 |
1x95RMC |
11.3 +0.20 |
4.5 |
21.5 |
35 |
25.4 |
30.2 |
1160 |
2.85 |
0.45 |
1x120RMC |
12.5 +0.20 |
4.5 |
22.7 |
50 |
26.6 |
31.4 |
1400 |
3.6 |
0.47 |
1x150RMC |
14.2 +0.20 |
4.5 |
24.4 |
50 |
28.3 |
33.1 |
1520 |
4.5 |
0.50 |
1x185RMC |
15.8 +0.20 |
4.5 |
26.0 |
50 |
29.9 |
34.7 |
1660 |
5.55 |
0.52 |
1x240RMC |
17.9 +0.10 |
4.5 |
28.1 |
50 |
32.0 |
36.8 |
1870 |
7.2 |
0.55 |
1x300RMC |
20.0 +0.30 |
4.5 |
30.2 |
50 |
34.1 |
38.9 |
2080 |
9 |
0.58 |
1x400RMC |
22.9 +0.30 |
4.5 |
33.1 |
50 |
37.0 |
41.8 |
2390 |
12 |
0.63 |
1x500RMC |
25.7 +0.40 |
4.5 |
36.4 |
50 |
40.5 |
45.3 |
2810 |
15 |
0.68 |
1x630RMC |
29.3 +0.50 |
4.5 |
40.3 |
50 |
44.4 |
49.3 |
3310 |
18.9 |
0.74 |
1x800RMC |
33.0 +0.50 |
4.5 |
44.4 |
50 |
48.5 |
53.6 |
3920 |
24 |
0.80 |
1x1000RMC |
38.0 +0.50 |
4.5 |
49.4 |
50 |
53.5 |
59.0 |
4680 |
30 |
0.89 |
COPPER CONDUCTOR - Round, stranded and compacted conductor - Class 2 YHKXS acc . to ZN-TF-501:2002
2XSY acc . to IEC 60502-2:2005 and BS 6622:2007
N2XSY acc . to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter |
Insulation |
Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying |
||
Thickness |
Diameter over insulation |
Cross sectional area |
Diameter over metallic screen |
||||||
mm2 |
mm |
mm2 |
mm |
mm |
kg/km |
kN |
m |
||
1x35RMC |
7.0 +0.15 |
4.5 |
17.2 |
16 |
21.1 |
25.9 |
920 |
1.75 |
0.39 |
1x50RMC |
8.25 +0.20 |
4.5 |
18.5 |
16 |
22.4 |
27.1 |
1060 |
2.5 |
0.41 |
1x70RMC |
9.6 +0.20 |
4.5 |
19.8 |
25 |
23.7 |
28.5 |
1370 |
3.5 |
0.43 |
1x95RMC |
11.5 +0.20 |
4.5 |
21.7 |
35 |
25.6 |
30.4 |
1740 |
4.75 |
0.46 |
1x120RMC |
12.9 +0.25 |
4.5 |
23.1 |
50 |
27.0 |
31.8 |
2140 |
6 |
0.48 |
1x150RMC |
14.5 +0.30 |
4.5 |
24.7 |
50 |
28.6 |
33.4 |
2430 |
7.5 |
0.50 |
1x185RMC |
16.0 +0.30 |
4.5 |
26.2 |
50 |
30.1 |
34.9 |
2790 |
9.25 |
0.52 |
1x240RMC |
18.5 +0.30 |
4.5 |
28.7 |
50 |
32.6 |
37.4 |
3350 |
12 |
0.56 |
1x300RMC |
20.5 +0.30 |
4.5 |
30.7 |
50 |
34.6 |
39.4 |
3940 |
15 |
0.59 |
1x400RMC |
23.5 +0.30 |
4.5 |
33.7 |
50 |
37.6 |
42.4 |
4810 |
20 |
0.64 |
1x500RMC |
26.5 +0.40 |
4.5 |
37.2 |
50 |
41.3 |
46.1 |
5920 |
25 |
0.69 |
1x630RMC |
30.3 +0.40 |
4.5 |
41.3 |
50 |
45.4 |
50.3 |
7290 |
31.5 |
0.75 |
1x800RMC |
34.6 +0.50 |
4.5 |
46.0 |
50 |
50.1 |
55.4 |
9010 |
40 |
0.83 |
1x1000RMC |
38.2 +0.40 |
4.5 |
49.6 |
50 |
53.7 |
59.2 |
10930 |
50 |
0.89 |
ALUMINIUM CONDUCTOR - Round, stranded and compacted conductor - Class 2 XUHAKXS acc. ZN-TF-501:2002
A2XS(F)2Y acc. to IEC 60502-2:2005 and BS 6622:2007
NA2XS(F)2Y acc. to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter | Insulation | Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying | ||
Thickness | Diameter over insulation | Cross sectional area | Diameter over metallic screen | ||||||
mm2 | mm | mm2 | mm | mm | kg/km | kN | m | ||
1x50RMC | 8.25 +0.10 | 4.5 | 18.5 | 16 | 22.6 | 28.1 | 720 | 1.5 | 0.42 |
1x70RMC | 9.5 +0.20 | 4.5 | 19.7 | 25 | 23.8 | 29.4 | 890 | 2.1 | 0.44 |
1x95RMC | 11.3 +0.20 | 4.5 | 21.5 | 35 | 25.6 | 31.2 | 1100 | 2.85 | 0.47 |
1x120RMC | 12.5 +0.20 | 4.5 | 22.7 | 50 | 26.8 | 32.4 | 1330 | 3.6 | 0.49 |
1x150RMC | 14.2 +0.20 | 4.5 | 24.4 | 50 | 28.5 | 34.1 | 1440 | 4.5 | 0.51 |
1x185RMC | 15.8 +0.20 | 4.5 | 26.0 | 50 | 30.1 | 35.7 | 1580 | 5.55 | 0.54 |
1x240RMC | 17.9 +0.10 | 4.5 | 28.1 | 50 | 32.2 | 37.8 | 1780 | 7.2 | 0.57 |
1x300RMC | 20.0 +0.30 | 4.5 | 30.2 | 50 | 34.3 | 39.9 | 1990 | 9 | 0.60 |
1x400RMC | 22.9 +0.30 | 4.5 | 33.1 | 50 | 37.2 | 42.8 | 2300 | 12 | 0.64 |
1x500RMC | 25.7 +0.40 | 4.5 | 36.4 | 50 | 40.7 | 46.3 | 2710 | 15 | 0.69 |
1x630RMC | 29.3 +0.50 | 4.5 | 40.3 | 50 | 44.6 | 50.3 | 3190 | 18.9 | 0.75 |
1x800RMC | 33.0 +0.50 | 4.5 | 44.4 | 50 | 48.7 | 54.6 | 3780 | 24 | 0.82 |
1x1000RMC | 38.0 +0.50 | 4.5 | 49.4 | 50 | 53.7 | 60.0 | 4510 | 30 | 0.90 |
ALUMINIUM CONDUCTOR - Round, stranded and compacted conductor - Class 2 YHAKXS acc . to ZN-TF-501:2002
A2XSY acc . to IEC 60502-2:2005 and BS 6622:2007NA2XSY acc . to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter | Insulation | Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying | ||
Thickness | Diameter over insulation | Cross sectional area | Diameter over metallic screen | ||||||
mm2 | mm | mm2 | mm | mm | kg/km | kN | m | ||
1x50RMC | 8.25 +0.10 | 5.5 | 20.5 | 16 | 24.4 | 29.1 | 860 | 1.5 | 0.44 |
1x70RMC | 9.5 +0.20 | 5.5 | 21.7 | 25 | 25.6 | 30.4 | 1040 | 2.1 | 0.46 |
1x95RMC | 11.3 +0.20 | 5.5 | 23.5 | 35 | 27.4 | 32.2 | 1260 | 2.85 | 0.48 |
1x120RMC | 12.5 +0.20 | 5.5 | 24.7 | 50 | 28.6 | 33.4 | 1500 | 3.6 | 0.50 |
1x150RMC | 14.2 +0.20 | 5.5 | 26.4 | 50 | 30.3 | 35.1 | 1620 | 4.5 | 0.53 |
1x185RMC | 15.8 +0.20 | 5.5 | 28.0 | 50 | 31.9 | 36.7 | 1770 | 5.55 | 0.55 |
1x240RMC | 17.9 +0.10 | 5.5 | 30.1 | 50 | 34.0 | 38.8 | 1980 | 7.2 | 0.58 |
1x300RMC | 20.0 +0.30 | 5.5 | 32.2 | 50 | 36.1 | 40.9 | 2200 | 9 | 0.61 |
1x400RMC | 22.9 +0.30 | 5.5 | 35.1 | 50 | 39.0 | 43.8 | 2510 | 12 | 0.66 |
1x500RMC | 25.7 +0.40 | 5.5 | 38.4 | 50 | 42.5 | 47.3 | 2940 | 15 | 0.71 |
1x630RMC | 29.3 +0.50 | 5.5 | 42.3 | 50 | 46.4 | 51.3 | 3460 | 18.9 | 0.77 |
1x800RMC | 33.0 +0.50 | 5.5 | 46.4 | 50 | 50.5 | 55.8 | 4100 | 24 | 0.84 |
1x1000RMC | 38.0 +0.50 | 5.5 | 51.4 | 50 | 55.5 | 61.0 | 4850 | 30 | 0.92 |
COPPER CONDUCTOR - Round, stranded and compacted conductor - Class 2 YHKXS acc . to ZN-TF-501:2002
2XSY acc . to IEC 60502-2:2005 and BS 6622:2007
N2XSY acc . to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter | Insulation | Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying | ||
Thickness | Diameter over insulation | Cross sectional area | Diameter over metallic screen | ||||||
mm2 | mm | mm2 | mm | mm | kg/km | kN | m | ||
1x35RMC | 7.0 +0.15 | 5.5 | 19.2 | 16 | 23.1 | 27.9 | 990 | 1.75 | 0.42 |
1x50RMC | 8.25 +0.20 | 5.5 | 20.5 | 16 | 24.4 | 29.1 | 1140 | 2.5 | 0.44 |
1x70RMC | 9.6 +0.20 | 5.5 | 21.8 | 25 | 25.7 | 30.5 | 1450 | 3.5 | 0.46 |
1x95RMC | 11.5 +0.20 | 5.5 | 23.7 | 35 | 27.6 | 32.4 | 1830 | 4.75 | 0.49 |
1x120RMC | 12.9 +0.25 | 5.5 | 25.1 | 50 | 29.0 | 33.8 | 2230 | 6 | 0.51 |
1x150RMC | 14.5 +0.30 | 5.5 | 26.7 | 50 | 30.6 | 35.4 | 2520 | 7.5 | 0.53 |
1x185RMC | 16.0 +0.30 | 5.5 | 28.2 | 50 | 32.1 | 36.9 | 2890 | 9.25 | 0.55 |
1x240RMC | 18.5 +0.30 | 5.5 | 30.7 | 50 | 34.6 | 39.4 | 3460 | 12 | 0.59 |
1x300RMC | 20.5 +0.30 | 5.5 | 32.7 | 50 | 36.6 | 41.4 | 4060 | 15 | 0.62 |
1x400RMC | 23.5 +0.30 | 5.5 | 35.7 | 50 | 39.6 | 44.4 | 4940 | 20 | 0.67 |
1x500RMC | 26.5 +0.40 | 5.5 | 39.2 | 50 | 43.3 | 48.1 | 6050 | 25 | 0.72 |
1x630RMC | 30.3 +0.40 | 5.5 | 43.3 | 50 | 47.4 | 52.5 | 7460 | 31.5 | 0.79 |
1x800RMC | 34.6 +0.50 | 5.5 | 48.0 | 50 | 52.1 | 57.4 | 9170 | 40 | 0.86 |
1x1000RMC | 38.2 +0.40 | 5.5 | 51.6 | 50 | 55.7 | 61.4 | 11130 | 50 | 0.92 |
ALUMINIUM CONDUCTOR - Round, stranded and compacted conductor - Class 2 YHAKXS acc . to ZN-TF-501:2002
A2XSY acc . to IEC 60502-2:2005 and BS 6622:2007
NA2XSY acc . to DIN VDE 0276-620 and HD 620S2:2010 part 10 section C
Conductor – nominal cross sectional area |
Conductor diameter | Insulation | Metallic screen |
Cable diameter D e |
Cable weight |
Maximum cable pulling force |
Recommended min. bending radius for laying | ||
Thickness | Diameter over insulation | Cross sectional area | Diameter over metallic screen | ||||||
mm2 | mm | mm2 | mm | mm | kg/km | kN | m | ||
1x50RMC | 8.25 +0.10 | 8.0 | 25.5 | 16 | 29.4 | 34.1 | 1080 | 1.5 | 0.51 |
1x70RMC | 9.5 +0.20 | 8.0 | 26.7 | 25 | 30.6 | 35.4 | 1270 | 2.1 | 0.53 |
1x95RMC | 11.3 +0.20 | 8.0 | 28.5 | 35 | 32.4 | 37.2 | 1500 | 2.85 | 0.56 |
1x120RMC | 12.5 +0.20 | 8.0 | 29.7 | 50 | 33.6 | 38.4 | 1750 | 3.6 | 0.58 |
1x150RMC | 14.2 +0.20 | 8.0 | 31.4 | 50 | 35.3 | 40.1 | 1890 | 4.5 | 0.60 |
1x185RMC | 15.8 +0.20 | 8.0 | 33.0 | 50 | 36.9 | 41.7 | 2050 | 5.55 | 0.63 |
1x240RMC | 17.9 +0.10 | 8.0 | 35.1 | 50 | 39.0 | 43.8 | 2280 | 7.2 | 0.66 |
1x300RMC | 20.0 +0.30 | 8.0 | 37.2 | 50 | 41.1 | 45.9 | 2510 | 9 | 0.69 |
1x400RMC | 22.9 +0.30 | 8.0 | 40.1 | 50 | 44.0 | 48.8 | 2850 | 12 | 0.73 |
1x500RMC | 25.7 +0.40 | 8.0 | 43.4 | 50 | 47.5 | 52.7 | 3350 | 15 | 0.79 |
1x630RMC | 29.3 +0.50 | 8.0 | 47.3 | 50 | 51.4 | 56.7 | 3890 | 18.9 | 0.85 |
1x800RMC | 33.0 +0.50 | 8.0 | 51.4 | 50 | 55.5 | 61.0 | 4550 | 24 | 0.92 |
1x1000RMC | 38.0 +0.50 | 8.0 | 56.4 | 50 | 60.5 | 66.4 | 5370 | 30 | 1.00 |