Photovoltaic PV H1Z2Z2-K Cable

Photovoltaic PV H1Z2Z2-K Cable solar cables price from cable manufactrer in China.
Overview

Key Features: Photovoltaic PV H1Z2Z2-K Cable

  • Application: DC Power Cable for the interconnection of photovoltaic systems.
  • Suitability: For fixed installations, internal and external, including direct burial.
  • Standards & Voltage Ratings: EN 50618. Flame retardant to IEC/EN 60332-1-2. Low Smoke Zero Halogen to IEC/EN 60754-1/2, IEC/EN 61034-1/2. Water Resistant to AD8. Rated AC: 0.6/1kV and DC: 900/1800V.
  • Construction: Class 5 Flexible Tinned Copper conductor, Halogen Free Cross-linked compound insulation, and Halogen Free Cross-linked Flame Retardant compound outer sheath.
  • Details: Single core. 'Double-insulation' construction offering increased safety. TUV approved. UV and Ozone resistant. Full technical support provided.

PV DC Solar Cable Specification

Our photovoltaic (PV) cables are intended for interconnecting power supplies within renewable energy photovoltaic systems such as solar panel arrays in solar energy farms. They are used for installation at Direct Current (DC) side. They are suitable for fixed installations, both internal and external, and within conduits or systems. Their robust sheathing and impact testing means they are suitable for direct burial in ground applications.

They are manufactured in accordance with European Standard EN 50618 and the harmonised designation H1Z2Z2-K. These cables are TUV approved, and this standard supersedes the previous TÜV approved PV1-F cable.

The compounds used in the insulation and outer sheathing are halogen free cross-linked, hence the reference to these cables as "cross-linked solar power cables". The EN50618 standard sheathing has a thicker wall than the PV1-F cable version. The cable sheathing is rated AD8 Water Resistant.

As with the previous TÜV PV1-F cable, the EN50618 PV cable benefits from a double-insulation offering increased safety. The Low Smoke Zero Halogen (LSZH) insulation and sheathing makes them suitable for use in environments where corrosive smoke would present a risk to human life in the event of fire. 

H1Z2Z2-K Cable Voltage Rating

With a nominal DC voltage of up to 1.5kV between conductors, and not exceeding 1800V between conductor and earth, these cables are required to be tested at a voltage of 11kV AC 50Hz. They have an operating temperature range of -40oC to +90℃. 


Construction Table

 Photovoltaic Cable CSPhotovoltaic PV H1Z2Z2-K Cable
VOLTAGE

AC: 0.6/1kV
DC: 900/1800V

CONDUCTOR

Class 5 Flexible Stranded Tinned Copper

INSULATION

Halogen-Free Cross-Linked Compound

OUTER SHEATH

Halogen-Free Cross-Linked, Flame Retardant Compound


Parameter

NOMINAL CROSS SECTIONAL AREA mm2

NOMINAL OVERALL DIAMETER mm

NOMINAL WEIGHT kg/km

TENSILE STRENGTH IN OPERATION N

1.5

4.6

36

22

2.5

5.0

46

37

4

5.6

62

60

6

6.1

82

90

10

7.1

125

150

16

8.5

190

240

25

10.4

285

375

35

11.5

385

525

50

13.7

540

750

70

15.8

740

1050

95

17.3

965

1350

120

19.1

1210

1800

150

21.4

1495

2250

185

24.9

1885

2775

240

27.3

2395

3600